For further sizes and specifications in the KASTOcross range click on the technical data sheet downloads above. |
| Cutting range flat |
660 x 1660 mm |
| Clamping range |
0 – 1660 mm |
| Min. height of plate |
10 mm |
| Shortest cut-off length |
20 mm |
| Overall Dimensions |
| Width of machine approx. |
2400 mm |
| Depth of machine incl. chip conveyor approx. |
9050 mm |
| Depth of machine to pull out the chip conveyor approx. |
12050 mm |
| Height of machine approx. |
3600 mm |
| Material support height approx. |
1650 mm |
| Total weight of the machine approx. |
14000 kg |
| Driving power |
10.0 kW |
| Total power |
18.0 kW |
| Minimum remnant length individual cut |
25 mm |
| Cutting speed infinitely variable |
12 – 120 m/min with 50 Hz |
| Cutting feed infinitely variable |
0.5 – 250 mm/min |
| Dimensions of saw blade approx. |
9260 x 54 x 1.6 mm |
| Or approx. |
9260 x 67 x 1.6 mm |
| Saw blade guide |
carbide tipped, exchangeable |
| Saw blade tension |
hydraulic |
| Saw blade cleaning |
By means of easy to exchange brush, motor-driven |
| Coolant |
Supply through 2 coolant nozzles, volume of coolant tank approx. 400 l, pump capacity 100 l/min with pump lift of 5 m |
| Energy Supply |
| Mains voltage |
In accordance with EN 60204
400 V three-phase current (-10 %, +6 %)
Control voltage 24 V-DC
The customer will be notified of the connection value in kVA after the scope of supply has been finalized.
On request other voltages for an extra charge |
| Mains frequency |
50 Hz (-1 %, +1 %; transient –2 %, +2 %) |
| Type of mains |
TN mains according to IEC 364/VDE 0100
The power is supplied from the mains to the switching cabinets including advance fusing by the customer. The position of the switch cabinet is to be seen from the layout. |
Protective measures
against indirect contact |
Over-current protector (zero balancing).
The mains supply of the operator (size and characteristic of the main fuse selected as well as the total impedance of PE and outer conductor in the supply line to the machine) has to be designed in such a way that the permissible shutdown time in the event of an error is not exceeded.
The use of a differential current switch in the mains incoming supply is not permitted. |
| Safety requirements |
The offered machine corresponds with the valid safety requirements according to DIN EN ISO 12100-1, DIN EN ISO 12100-2 |
| Painting |
Machine RAL 7035, light grey, structural painting |